For HSE, QA and audit teams

Verifying cleaning records and reading the findings.

You do not have to rely on our word for any result. This page sets out how to confirm a record has not been altered, what evidence sits behind each section, and how to read the findings in the sample report.

1 · Integrity check

Confirm the record is unchanged

Measurements and customer data stay private. Only a fingerprint (hash) of the signed manifest goes on-chain, so you can verify integrity without publishing operational data.

  1. 01

    Obtain the record package

    Request the report PDF, the evidence files and the signed manifest for the report number and revision you are reviewing. Access is granted per tank, per cleaning cycle.

  2. 02

    Recompute file hashes

    Calculate the SHA-256 hash of the report and each evidence file with any standard tool (for example sha256sum or certutil). Every hash must match the corresponding entry in the manifest.

  3. 03

    Check the manifest signatures

    Confirm the manifest is signed by the operator and the QA reviewer named in the report, and that the signing keys are the ones registered for your contract.

  4. 04

    Match the on-chain fingerprint

    Look up the transaction ID listed in the report on a public block explorer. The fingerprint stored in the transaction must equal the manifest hash, and the block time must fall after the QA release time.

  5. 05

    Confirm the revision chain

    If the report is Revision 2 or later, each revision references the previous record. Earlier revisions remain verifiable; nothing is overwritten.

The sample report CTR-DEMO-2026-001 is illustrative: it has no signatures, hashes or on-chain transaction, so these checks cannot be run against it.

2 · Audit evidence

What to review behind each section

Report sectionEvidence providedWhat to check
Removed materialsScale readings with gross and tare, scale calibration reference, seal numbers, custody transfer form and, once issued, the waste classification and disposal receipt.Net masses reconcile with gross − tare; seal numbers match the transfer form; receiving party and time are recorded.
Cleanliness verificationSample chain-of-custody form, laboratory reports with method and reporting limit, sensor readings with calibration certificates, and dated images per zone.Sample IDs, locations and times are consistent across the custody form and lab report; instruments were in calibration on the day.
Surface analysisCoating gauge readings, optical profile scans and images, each tagged with zone, area and position.Inspected area adds up to the stated coverage; any inaccessible zone is declared, not omitted.
Review and releaseTime-stamped operator close-out, custody handover and QA disposition against the agreed acceptance plan.Release happens after all results are in; open actions are listed rather than closed silently.

3 · Interpreting findings

How to read the sample report

PASS against a sample limit
The result met the limit in the agreed acceptance plan (e.g. chlorides 1.2 mg/L against ≤ 2.0 mg/L). It confirms that check only. It does not certify suitability for every cargo or replace your own release procedure.
Not detected; reporting limit stated
The analyte was below what the method can report (e.g. ethylene glycol < 0.5 mg/L). Read it as "below 0.5 mg/L", not as zero. Check that the reporting limit sits below your acceptance limit.
Wash effluent mass
Includes the wash water we added. Use the residue and debris batches for the quantity removed from the tank, and the effluent mass for wastewater handling and disposal records.
Classification pending
No waste category is assumed until the receiving facility or laboratory issues it. Track the disposal receipt as an open item for your environmental records.
Local wear; trend at next service
Coating is within the measured range with no exposed steel seen. No action now; compare readings in the same zone at the next clean.
Pit-like features flagged; engineer review
Optical estimates (e.g. 0.3–0.5 mm) indicate a possible defect but do not establish remaining steel thickness. Treat it as an open maintenance action until confirmed by a qualified inspection method such as UT gauging.
QA accepted with open action
The cleaning results met the acceptance plan, while a separate maintenance item remains open. Tank release for cargo and maintenance planning are separate decisions for your team.

Acceptance limits are agreed per contract and cargo transition. A report supports, but does not replace, your own release decision, permit-to-work and regulatory obligations.