Auditable by design

Tamper-evident cleaning records.

Each clean produces a signed record: what was in the tank, what was removed, what surface was cleaned and what the sensors measured. Its fingerprint is written on-chain, so anyone you share it with can confirm it hasn't changed.

  • Cargo-change certificates for shippers and food customers
  • Waste and disposal evidence for environmental reporting
  • Coating condition history for vetting and maintenance
  • Your data stays private — only proofs go on-chain

Inside a cleaning report

From removed residue to a traceable result.

Material batches and custody transfers. Test methods, results and limits. Surface maps, findings and review history — linked to one tank and one cleaning cycle.

View sample report ↓

Illustrative report · Not a certificate

Sample cleaning report

CTR-DEMO-2026-001 / Revision 1

Fictional tank, measurements, people and evidence references. Limits are illustrative, not universal cleaning standards. No laboratory certification, digital signature or blockchain transaction has been issued for this sample.

Tank / location
T-4417 · cargo tank 6P / Rotterdam (demo)
Cargo transition
Ethylene glycol → vegetable oil
Cleaning window (UTC)
24 Nov 2026 · 08:00–11:35
Surface / coverage
Coated steel · 412.6 m² cleaned and scanned
Cleaning method
Detergent wash, fresh-water rinse, dry
Robot / operator
CTR-R07 / Alex Morgan (fictional)
Acceptance plan
AP-DEMO-01 · agreed cargo-change limits
QA disposition
Sample acceptance passed; maintenance follow-up

01 / MATERIALS REMOVED

Measured, contained, handed over.

Removed materials and custody records
Material / batchNet massMeasurementContainment / destinationEvidence
Cargo residue · W-0115.8 kgGross 20.8 − tare 5.0 kgSealed drum D-01 · licensed treatmentWM-01 / scale SC-02
Sediment / coating debris · W-022.5 kgGross 4.5 − tare 2.0 kgSealed drum D-02 · classification pendingWM-02 / scale SC-02
Collected wash effluent · W-031,240.0 kgGross 1,380.0 − tare 140.0 kgIBC-03 · wastewater treatmentWM-03 / scale SC-04

18.3 kg of residue and debris; 1,240.0 kg of wash effluent recorded separately. Total collected: 1,258.3 kg. Effluent includes added wash water; it is not a measurement of cargo residue alone.

Custody: sealed at 11:10 UTC by Alex Morgan; received at 11:25 UTC by Sam Lee (fictional), Demo Waste Services. Transfer WT-DEMO-01. Final waste classification and disposal receipt remain pending; no non-hazardous classification is assumed.

02 / CLEANLINESS VERIFICATION

Results against an agreed acceptance plan.

Illustrative cleanliness verification measurements
Check / methodSample locationResultSample limitStatus / evidence
Chlorides · ion chromatographyWall wash WW-01–03Maximum 1.2 mg/L≤ 2.0 mg/LPASS
LAB-DEMO-01
Ethylene glycol · GC analysisWall wash WW-01–03Not detected; reporting limit 0.5 mg/L< 1.0 mg/LPASS
LAB-DEMO-02
Final rinse pH · calibrated probeDrain sample FR-017.16.5–8.5PASS
SENSOR-01
Visual residue / dryness · cameraAll mapped zones A–DNo visible residue or standing waterNone visiblePASS
IMG-01–04

Samples collected at 10:40 UTC from upper wall (A), lower wall (B) and sump (D). Chain of custody COC-DEMO-01 links samples to the tank and cleaning cycle. Instruments SC-02, SC-04 and PH-01 reference fictional calibration records CAL-01–03.

These results illustrate the agreed checks only; they do not establish food-grade suitability, microbiological safety or compliance for every cargo. Actual release requires the operator’s complete cargo-specific acceptance criteria.

03 / SURFACE ANALYSIS

Findings tied to a location and follow-up.

Sample surface analysis and maintenance findings
Zone / inspected areaMethod / resultFindingAction / evidence
A · upper walls / 120.0 m²Coating gauge · 285–320 µmNo visible coating breaksBaseline retained / SCAN-A
B · lower walls / 150.0 m²Coating gauge · 272–310 µmLocal wear; no exposed steel seenTrend at next service / SCAN-B
C · weld band / 42.6 m²Optical profile · estimated depth 0.3–0.5 mmThree pit-like features flaggedEngineer review; confirm depth / SCAN-C, IMG-C1–3
D · floor and sump / 100.0 m²Coating gauge · 280–305 µmNo visible delaminationBaseline retained / SCAN-D

Coverage: 412.6 / 412.6 m² mapped; no inaccessible zones in this example. Zone C features are at weld W-C-03, 1.2–1.6 m above the floor. Optical estimates do not establish remaining steel thickness or structural fitness; targeted inspection is required.

Review & release trail

  1. 11:10 UTC · Operator closes cleaning cycle; material batches sealed.
  2. 11:25 UTC · Waste custody handover recorded; disposal receipt pending.
  3. 11:35 UTC · QA reviewer Jamie Chen (fictional) accepts sample cleaning results under AP-DEMO-01. Zone C maintenance action remains open.

Revision 1 · No amendments. In a live report, later corrections would create a new revision linked to the previous record, preserving the original evidence.

Evidence & on-chain audit trail

Evidence bundle
EV-CTR-DEMO-2026-001
Document fingerprint / signatures
Not generated — illustrative report
Network / transaction / block
None — not published on-chain

For a live audit, the reviewer compares the report and evidence-file hashes with a signed manifest, then checks its on-chain fingerprint and transaction confirmation. Measurements and customer data remain private; a blockchain entry proves record integrity, not the accuracy of the measurements.

Sample evidence register

Reference names only; no underlying files or genuine signatures are attached to this fictional example.

  • WM-01–03 / WT-DEMO-01 · weights, seals and custody transfer
  • COC-DEMO-01 / LAB-DEMO-01–02 · sample custody and analyses
  • SENSOR-01 / CAL-01–03 · rinse readings and calibration
  • SCAN-A–D / IMG-01–04, IMG-C1–3 · surface maps and images

Multi-year service agreements

Documented cleans, without confined-space entry.

Request a quote